HP StorageWorks Fabric OS 5.3.
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P. © Copyright 2007 Brocade Communications Systems, Incorporated Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
Version 5.3.0d Effective date December 2007 Description Fabric OS 5.3.0d is a patch release that contains fixes since the release of Fabric OS 5.3.0c. There is no new device support added with this release for HP StorageWorks platforms. Update recommendations HP strongly recommends that users upgrade to Fabric OS 5.3.0d as soon as possible, particularly if your model is the Brocade 4Gb SAN Switch for HP c-Class BladeSystem (Brocade 4024) and you are running a version older than 5.3.0b.
Support for embedded switch models The B-Series embedded switches have transitioned from supporting the Fabric OS 5.0.5 stream only, to operating with Fabric OS 5.2.1b and later. The B-Series embedded switch models include: • Brocade 4Gb SAN Switch for HP p-Class BladeSystem (Brocade 4012) • Brocade 4Gb SAN Switch for HP c-Class BladeSystem (Brocade 4024) NOTE: The Fabric OS 5.0.5 stream remains active for the Core Switch 2/64 and for the SAN Director 2/128 in chassis modes 3 and 4.
• Access Gateway mode support on the HP StorageWorks 4/16 SAN Switch (not supported on the 4/8 SAN Switch) • Access Gateway enhancements: • Web Tools support • Fabric Manager support • NPIV on F_ports • Fibre Channel Routing enhancements • IP Broadcast zone support • IP over FC also via FCR • IP Filter support (formerly MAC and Management port ACLs in Secure Fabric OS (SFOS)) • Support for FCS with base Fabric OS (formerly in SFOS) • Support for multiple NTP servers • Port mirroring for 4/32B switch • Secur
requiring a domain and the associated fabric rebuild traffic that is prevalent when switches are powered on, or added, or removed from a fabric. Refer to the Brocade Access Gateway Administrator’s Guide available on http://www.hp.com/go/san for more information. Access Gateway support in non-Brocade fabrics In addition to being supported in Brocade fabrics, Access Gateway is supported for connectivity to the following: • McDATA fabrics running EOS 09.00.xx with Brocade FOS 5.2.
• Protected-Extensible Authentication Protocol (P-EAP with MSCHAP-v2) support for RAdmin DomainIUS. • DH-CHAP now supported for authentication of HBAs and end-devices in addition to switches • Additional password security options • Lockout of Admin users that fail authorization. • Flexible E_Port authentication settings, allowing better interoperability options for fabrics with varying levels of support. Certificate authentication is now optional. • Auditing of authorization attempts.
Prerequisites Table 1 summarizes current Fabric OS firmware versions. However, HP recommends using the latest supported firmware release versions to get the greatest benefit from the SAN. For a list of retired products, visit the HP web site http://www.hp.com. IMPORTANT: The Fabric OS versions listed in the Earliest compatible version column below are the earliest versions supported by HP at the time 5.3.0d released.
NOTE: The B-Series MP Router Blade (for use with the 4/256 Director only) must run Fabric OS 5.1.0d or later. Note that the Core Switch 2/64 does not support the B-Series MP Router Blade. Firmware upgrade instructions IMPORTANT: HP strongly recommends that users upgrade to Fabric OS 5.3.0d as soon as possible (particularly if your model is the Brocade 4Gb SAN Switch for HP c-Class BladeSystem and you are currently running a version of Fabric OS earlier than 5.3.0b). To access the latest Fabric OS 5.3.
Important notes Table 2 provides information relevant to the release. Table 2 Important release information Topic Description ipfilter command Starting with Fabric OS version 5.3.0, you can use the ipfilter command to block unauthorized Telnet access. The option to disable Telnet using the configure command is no longer available.
Topic Description 4/256 SAN Director Fans operate at the correct speed; that is, at maximum on bootup. However, this initial speed may trigger an error message that indicates that the speed is too high (Above threshold). Disregard this message. Fans operate at the correct speed; that is, at maximum on bootup. However, this initial speed may trigger an error message that indicates that the speed is too high (Above threshold). Disregard this message.
Topic Description FC4–16IP iSCSI Blade for the 4/256 SAN Director • Do not insert the Blade until the system is running Fabric OS 5.2.1b or later. • iSCSI virtual target creation involves adding LUNs to the virtual targets. The user discovers the LUNs by executing the fclunquery command. Testing has revealed that some devices do not respond properly to the LUN query. The user will need to use tools from the array vendor to determine LUN information required for iSCSI target creation.
Topic Description FC Routing • If an HP StorageWorks MP Router is present in the backbone fabric, the command fcrDisable may take up to 8 minutes to complete. If the MP Router is replaced by a B-Series MP Router Blade (FR4-18i) or an HP StorageWorks 400 MP Router, the command completes immediately. • EX_Port trunking is not enabled by default. • FCR switch does not support an edge fabric with one McDATA switch set to ‘never principal’. The EX_Port connected to that edge fabric will not come up.
Topic Description Scalability • Support for Default Zoning policies has been added to Fabric OS 5.1.0. Typically, when you issue the cfgDisable command in a large fabric with thousands of devices, the name server indicates to all hosts that they can communicate with each other. To ensure that all devices in a fabric do not see each other during a cfgDisable operation, you can activate a Default Zone with policy set to no access.
Topic Description Access Gateway Mode Port State When a disabled port on a switch in Access Gateway mode is connected to a configured loop HBA, the port state alternates between Nosync and Insync. The switchShow command displays the state of the remote HBA port that is continuously attempting to reconnect to the disabled port. Access Gateway mode is not supported in the p-Class BladeSystem if there are two half-height servers (BL3xp) in the same sleeve (Server Slot 1 and 9, or 2 and 10, etc).
Topic Description iSCSI • Enterprise storage array targets may not show up consistently in the disk management window of an iSCSI initiator when the same LUNs are mapped to two different virtual targets (VTs). When the initiator logs in to the VTs, the targets keep disappearing from the disk management window. If the session to one of the VTs is disconnected, the remaining VT appears and stabilizes in the disk management window.
Additional Fabric OS 5.3.0 enhancements Additional Fabric OS 5.3.0 enhancements include: • Provides new Fabric OS commands to rename an alias, a zone and a zone configuration. Zone –copy copies the zone object to a new zone object. Zoneobjectrename renames the zone object. • Detects and handles a corrupted zone configuration [under /etc/fabos/zone*] gracefully instead of rebooting. The switch also logs the error in RASLog. • Adds a new command that provides both the WWN and serial number of the switch.
Closed defect summary Solution New active CP got Oops and reboot during initialization after hafailover command issued. Fixed per Fabric OS 5.3.0 After CP reboot, VE tunnel doesn’t come up due to GE0 port on FR4-18i stuck in No_Sync state when using copper SFP’s. Fixed per Fabric OS 5.3.0 Switch doesn’t generate RSCN following zoning changes using cfgEnable in interop mode, resulting in no PLOGI from hosts, and no target discovery. Fixed per Fabric OS 5.3.
Closed defect summary Solution With large zoneset (over 1200 zones) API library crashes as the zone library does memcpy that doesn’t have terminating zero in the buffer. Fixed per Fabric OS 5.3.0 Change made in 5.2.0 to limit the number of FDISCs per unit of time, caused timeouts of NPIV logins in some BladeServer configurations with VC-FC. Fixed per Fabric OS 5.3.0. When FOS version prior to 5.2.0 is upgraded to a later version and the fabric.ops.mode.
Closed defect summary Solution Web Tools is missing “Invalid CRCS” under Fabric Watch end to end class pull down menu, due to missing “CRC Error” option. Fixed per Fabric OS 5.3.0 GUI component size squeezed due to lack of proper refresh after resizing. Fixed per Fabric OS 5.3.0 Errlog (raslog) messages not available for diagnosing DHCP problems. Fixed per Fabric OS 5.3.
Closed defect summary Solution If Dynamic Load Sharing (DLS) or In-Order Delivery is disabled, it can’t be enabled from Web Tools. However, it can be set/reset via CLI. Fixed per Fabric OS 5.3.0 Web Tools event filtering uses a time range of 0-11 rather than 1-12. In Web Tools Fabric Events and Events window, on invoking filter button and filtering based on “from” time or “to” time, on providing a time greater than 12 (e.g. 12:30 PM) will result in an error stating that time should be in range of 0-11.
Closed defect summary Solution SNMP traps repeatedly sent from the switch every 2 seconds when port taken out of a fault state implicitly by removing cable or module. Caused by too many port offline SCNs being sent out during port fault and recover when there is laser fault. Fixed per Fabric OS 5.3.0 Firmware downgrade to Fabric OS 5.1 or earlier is blocked even after ports 256 – 384 are removed from DCC policy created using [*] option. Currently have to delete DCC policy to avoid this.
Closed defect summary Solution Collecting supportsave info on 4/256 could cause error message on active CP console log. Fixed per Fabric OS 5.3.0 Host takes a long time to log in when disabled/unused GE-iSCSI ports have IP addresses configured to them. When host does a "SendTargets=All" those IP addresses will be in the list, but will be unreachable. Fixed per Fabric OS 5.3.0 After changing Backbone FID, switchshow doesn’t display LE port information for some EX or VEX ports.
Closed defect summary Solution When upgrading 4/256 to Fabric OS 5.2.0b from 5.2.0a, both ISL trunk connections to an edge switch connected to FC4-16IP were lost. Found in test lab and due to “lab mode” setting, not accessible to customers. Fixed per Fabric OS 5.3.0 Counter Address_err counting inappropriate data. Fixed per Fabric OS 5.3.0 When assigning IP address to a GE port with no cable connection, the FC4-16IP Blade incorrectly reports back to iSCSI initiator that port is valid.
Fabric OS 5.3.0a fixes Table 4 lists defects closed in the Fabric OS 5.3.0a firmware release. Table 4 Fabric OS 5.3.0a closed defects Closed defect summary Solution Iswitchd panic occurred during data migration with DMM when invalid frame issued to the switch. Fixed per Fabric OS 5.3.0a. Diag failure caused FA4-18 to report a fault after continuously running CP failover test. Fixed per Fabric OS 5.3.0a. Panic occurred on SAN Director 2/128 when running MS commands GPT/GPPN/GPS/GAPNL continuously.
Closed defect summary Solution When supportsave is run in a continuous loop, certain types of files are not detected which periodically generates the message: SupportSave completed sh: /tmp/supportSave_files/CONSOLE0: No such file or directory. File name can vary. Fixed per Fabric OS 5.3.0b. When the SFP/XFP power and voltage readings are above or below the range, an excessive number of alert messages were reported. Fixed per Fabric OS 5.3.0b.
Closed defect summary Solution After upgrading switches to FOS 5.3.0, the Web Tools GUI bar showing the "Initializing Switch Details" will get stuck at 93% if the client’s regional and language settings are set to some non-US languages such as Dutch, Russian, and Greek. English, French, German, Italian, Spanish, Portuguese, Simplified Chinese, Traditional Chinese, Japanese and Korean work fine. Fixed per Fabric OS 5.3.0c.