Brocade Secure Fabric OS Administrator's Guide - Supporting Fabric OS v3.2.0, v4.4.0, v5.0.1, v5.1.0, 5.2.0, and 5.3.0 (53-1000244-02, June 2007)

Secure Fabric OS Administrator’s Guide 75
53-1000244-02
4
One or more CLI sessions
is automatically logged
out.
Password might have been
modified for login account in
use, the secModeEnable
command might have been
issued, or switches might
have changed switch roles
(primary to backup, backup
to primary, and so forth).
Try closing and reopening CLI session.
On chassis-based
platforms, status
messages from any logical
switch are broadcast to
the serial console and
telnet sessions on all
other logical switches.
The status messages from
any logical switch are
normally broadcast to the
serial console and telnet
sessions on all logical
switches.
All broadcast messages display the switch instance.
Messages that originate from a switch instance other
than the one to which the telnet session is logged in
can be ignored.
CLI session freezes or
cannot be established
after secure mode is
enabled.
CP failed over and network
routing cache(s) require
updating.
Try closing and reopening CLI session. If this fails,
request that your LAN administrator refresh the
network router cache(s).
A policy that has been
created is not listed by the
secPolicyShow command.
The new policy was not
saved or activated.
Save or activate the policy changes by entering the
secPolicySave or secPolicyActivate command.
Incorrect policy name used. Verify that the correct policy name was used. Policy
names must be entered in all uppercase characters.
The message “The page
cannot be displayed” is
displayed when HTTP
access is attempted, and
response time is slow.
An HTTP policy has been
created but has no
members.
Add the desired members to the HTTP policy.
Unable to establish a
sectelnet/SSH session to
the IP address of the
active CP of a SilkWorm
24000 or 48000, or a
session to the standby CP
is disconnected when it
becomes the active CP.
sectelnet/SSH sessions
cannot be established to the
IP address of the active CP in
secure mode. This enables
enforcement of Telnet policy
for each logical switch.
Establish a sectelnet/SSH session to the IP
addresses of the logical switches or the standby CP
instead (if allowed by Telnet policy).
A security transaction
appears to have been lost.
One of the switches in the
fabric rebooted while the
transaction was in progress.
Wait for the switch to complete booting; then, reenter
the security command on the new primary FCS switch
to complete the transaction.
Fabric segments after
secure mode is enabled
on a SilkWorm 24000 or
48000 director.
CPs failed over during
process of enabling secure
mode.
Type secModeEnable again on the segmented
switch, using the same FCS list as used before.
Secure mode cannot be
enable on edge fabric
because the RC process
fails, security data is not
downloaded, and/or
domain 1 returns false.
secModeEnable quickmode
option was used on a Fabric
that is connected to a fibre
channel router. Quickmode
attempts add fibre channel
router's front domain to the
FCS policy.
Do not use quickmode to enable a secure mode on a
Fabric that has a fibre channel router connected to it.
TABLE 19 Recovery Processes (Continued)
Symptom Possible Causes Recommended Actions