Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.1a
Fabric OS v6.4.3f Release Notes v1.0 Page 107 of 149
Defect ID: DEFECT000319033
Technical Severity: High
Summary: Observed memory allocated to TSD was increasing over time which could potentially impact
switch over an extended duration
Symptom: Standby CP may reboot, and under some situations the active CP may fail and an HA Fail-
over may be observed
Feature: Fabric Infrastructure
Function: Time Server
Probability: Low
Found in Release: FOS6.4.1_fcoe
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000320335
Technical Severity: High
Summary: Host receiving "port type not detected" when in AG mode with policy of "auto"
Symptom: Enabled AG mode on the switch with AG policy of "auto", port on the switch then gets the
error "port type not detected".
Feature: Access Gateway Services
Function: Other
Probability: Low
Found in Release: FOS6.4.1
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000321597
Technical Severity: High
Summary: Detected termination of process lfmd followed by kernel panic while performing
supportsave
Symptom: The lfmd daemon is terminated while gathering supportsave and then kernel panic occurs.
This happens when there is large number of LISL configurations with virtual fabrics.
Feature: Logical Fabric
Function: LFMD
Probability: Low
Found in Release: FOS6.4.1_fcoe
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000322367
Technical Severity: High
Summary: PLOGI through VEX port of FCIP link were not being routed properly in a E2E topology.
Symptom: Host cannot see target in a E2E topology through VEX port of FCIP link.
Feature: FCIP
Function: FCIP Port
Probability: Medium
Found in Release: FOS6.4.1_fcoe
Where Else Fixed: FOS6.4.1 a