Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.3
Fabric OS v6.4.3f Release Notes v1.0 Page 71 of 149
Defect ID: DEFECT000387287
Technical Severity: Medium
Summary: OUI information changed for a specific OEM
Symptom: Updated OEM specific OUI name, no functional impact
Feature: OS Services
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000388283
Technical Severity: Medium
Summary: zoned caused switch panic
Symptom: During rename zone, add new zone name in list and then remove the old zone name,
switch panic.
Feature: Field Escalation
Function: Fabric Services
Probability: Low
Found in Release: FOS6.3.2
Defect ID: DEFECT000389202
Technical Severity: Medium
Summary: After changing F-port buffers via WebTools 0n 7800 cannot set buffers back to 8 (Default)
Symptom: Customer set F-port buffer credits to 16 using WebTools > port admin (advanced mode) >
F-port BB credit. Brocade recommended customer set the buffers back to 8 (default) state
but customer was unable to do so and get the following error message:"Error when
performing specified action for port 1 - F-Port BB credits with value less than 9 is not
allowed.
Feature: Field Escalation
Function: Web Management
Probability: Low
Found in Release: FOS7.0.0
Service Request ID: 710385
Defect ID: DEFECT000389307
Technical Severity: Medium
Summary: DCX (FS8-18) reporting FSS error in the RAS log after a "cryptocfg --commit" command
Symptom: Posting of FSS-1001 message with "(cvlmd) dropping HA data update" This can affect CP
to CP communications.
Workaround: The recovery procedure for the customer would be:
- Rebooting the standby CP
Feature: Field Escalation
Function: Encryption
Probability: Low
Found in Release: FOS6.4.2
Service Request ID: 709375