Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

72 Fabric OS Command Reference
53-1001337-01
bpPortLoopbackTest
2
Info: Vader port 5 recovering Rx Fifo
Ob1 portloopbacktest on ports 80-90 PASSED
Test Complete: bpportloopbacktest Pass 1 of 1
Duration 0 hr, 0 min & 24 sec (0:0:24:599).
Cleaning up after test.......
passed.
Diagnostics When it detects failures, the test may report one or more of the following error messages. If errors
persist, contact Technical Support.
DATA Data received does not match the data sent.
ERRSTAT Errors were found in the ASIC statistics.
INIT Port failed to initialize.
PORTDIED A previously initialized port went to an un-initialized state.
STATS Errors were found in the ASIC statistics.
TIMEOUT Did not receive a frame in the given timeout period.
XMIT Frame transmission failure.
See Also itemlist, portLoopbacktest