Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

96 Fabric OS Command Reference
53-1001337-01
chassisEnable
2
chassisEnable
Enables all user ports in a chassis.
Synopsis chassisenable
Description Use this command to enable a Virtual Fabric-aware chassis. All Fibre Channel ports that passed the
power-on self test (POST) are enabled. They may come online if connected to a device, or remain
offline if disconnected. Use chassisEnable to re-enable the chassis after making configuration
changes or running offline diagnostics.
If the chassis is partitioned into multiple logical switches and physically connected to multiple
logical fabrics, the logical switches rejoin their fabrics.
As each port is enabled, the front panel LED changes from slow flashing amber to green for online
ports, or to yellow for ports that do not initialize. Disconnected ports remain unlit. Loopback ports
are slow flashing green when online.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands none
Examples To enable a chassis:
switch:admin> chassisenable
See Also bladeDisable, bladeEnable, chassisDisable, switchShow, switchDisable, switchEnable,
switchCfgPersistentEnable, switchCfgPersistentDisable