Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

Fabric OS Command Reference 185
53-1001337-01
diagClearError
2
diagClearError
Clears the diagnostics failure status.
Synopsis diagclearerror [[--slot] slotnumber] -all
Description Use this command to clear the diagnostics failure status.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operand:
--slot slotnumber Specify the slot on which to clear the diagnostics failure status. The default is
set to 0 and designed to operate on fixed-port-count products.
-all If specified, all blades clear
.
If no operand is specified, the default is to clear all bad port flags.
Examples To clear the diag software flag:
switch:admin> diagclearerror 8
ERROR: DIAG CLEARERR
Diagnostics Errors Cleared, port: 8/31
Err# 0120041 081F
See Also none