Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

Fabric OS Command Reference 271
53-1001337-01
fcrPathTest
2
DIAG-STATS The ASIC internal error counters detected an error in the received frame. This
error is similar to ERRSTATS, but includes verifying the Tx/Rx frame count
statistics. The DIAG-STATS error can be caused by a faulty SFP or indicate
deeper problems in the main board or ASIC. Check for a faulty SFP. Replace
the cable or SFP if necessary.
DIAG-TIMEOUT The port failed to receive back a frame that was sent out. This can be caused
by a faulty SFP or indicate deeper problems in the main board or ASIC. Check
for a faulty SFP. Replace the SFP if necessary.
DIAG-XMIT The specified port failed to transmit frames. This usually indicates an ASIC
failure. Replace the blade or the switch.
See Also fcrChipTest, portLoopbackTest