Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

Fabric OS Command Reference 537
53-1001337-01
perfAddSCSIMonitor
2
perfAddSCSIMonitor
Adds a filter-based performance monitor for SCSI frame count.
Synopsis perfaddscsimonitor [slotnumber/]portnumber [alias]
Description Use this command to create a filter-based monitor that counts the number of SCSI traffic frames.
Only frames transmitted are counted.
Execution of this command displays a numeric key that uniquely identifies the monitor. Use the
perfMonitorShow command for a listing of valid keys and user-defined aliases.
Notes This command requires an Advanced Performance Monitoring license.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and
GbE ports.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operands:
slotnumber For bladed systems only, specifies the slot number of the port on which the
monitor is to be added, followed by a slash (/).
portnumber Specifies the number of the port on which the monitor is to be added, relative
to its slot for bladed systems. Use switchShow for a list of valid ports.
alias Specifies a name for this monitor. Strings exceeding 10 characters are
truncated. To accommodate spaces, the string must be surrounded by
quotation marks. Spaces count toward the character limit but are removed.
This operand is optional. The default alias is “SCSI Frame”.
Examples To add a SCSI traffic frame monitor to a port:
switch:admin> perfaddscsimonitor 2/4 “SCSI FR”
SCSI traffic frame monitor #0 added
See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor,
perfAddUserMonitor, perfAddWriteMonitor