Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

572 Fabric OS Command Reference
53-1001337-01
portBeacon
2
portBeacon
Sets port beaconing mode.
Synopsis chassisbeacon [mode] [slot]port
chassisbeacon --help
Description Use this command to enable or disable beaconing on a specified port.
When beaconing mode is turned on, the port LEDs flash green at various rates across the chassis.
The beaconing continues until you turn it off.
When beaconing mode is enabled on a port, the port LED flashes amber and green for 2.5 seconds
each in an alternating pattern. The beaconing mode continues until you turn it off. Beaconing mode
is useful if you are trying to locate a specific port.
Beaconing mode takes over the port LEDs. The normal flashing LED pattern associated with an
active, faulty, or disabled port is suppressed, and only the beaconing pattern is shown. Other
commands are still executable and functional. However, if diagnostic frame-based tests such as
portLoopbackTest are executed, the diagnostic LED pattern is interleaved with the beaconing
pattern.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operands:
slot For bladed systems only, specifies the slot number of the port group to
display, followed by a slash (/).
port Specifies the number of the port to be configured, relative to its slot for
bladed systems. Use switchShow for a listing of valid ports.
mode Specifies the port beaconing mode as one of the following:
--enable Enables beaconing mode on the specified port.
--disable Disables beaconing mode on the specified port.
--help Displays the command usage.
Examples To tenable beaconing mode on a port:
switch:admin> portbeacon --enable 1/0
To disable beaconing mode on a port:
switch:admin> chassisbeacon --disable 2/1
See Also chassisBeacon, switchBeacon