Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

Fabric OS Command Reference 635
53-1001337-01
portCfgShow
2
To display VLAN tagging configured on a Brocade FR4-18i FC Router blade (refer to the portCfg help
page for an explanation of the displayed parameters):
switch: admin> portcfgshow vlantag 8/ge0
Port: 8/ge0
IpIfAddress VlanId L2 CoS Dest IP Address Flags
-----------------------------------------------------
192.168.10.1 100 7 192.168.10.1 App
192.168.10.1 100 3 0.0.0.0 Perm
To display inband management interfaces configured on the Brocade 7500:
switch:admin> portcfgshow inbandmgmt ge1
Inband management: Enabled
Port: ge1
CP Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.1 255.255.255.252 1500
Port: ge1
GE Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.255.2 255.255.255.252 1500
See Also portCfg, portCfgCreditRecovery, portCfgEport, portCfgGport, portCfgLongDistance,
portCfgLPort, portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort