Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

702 Fabric OS Command Reference
53-1001337-01
portShow
2
To display an FCIP tunnel with FICON disabled:
switch:admin> portshow fciptunnel 16
-------------------------------------------
Tunnel ID: 16
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
To display an FCIP tunnel with additional circuit information:
switch:admin> portshow fciptunnel 17 -c
-------------------------------------------
Tunnel ID: 17
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
-------------------------------------------
Circuit ID: 17.0
Circuit Num: 0
Admin Status: Enabled
Oper Status: Up
Remote IP: 100.83.0.100
Local IP: 100.80.0.100
Metric: 0
Min Comm Rt: 150000
Max Comm Rt: 150000
SACK: On
Min Retrans Time: 100
Max Retransmits: 8
Keepalive Timeout: 5000
Path MTU Disc: 0
VLAN ID: 0
L2CoS: F: 0 H: 0 M: 0 L: 0
DSCP: F: 0 H: 0 M: 0 L: 0
Flags: 0x00000000
-------------------------------------------