sfpShow
2
To display detailed information for GbE port 0 on a Brocade 7500:
switch:admin> sfpshow ge0
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist
Encoding: 1 8B10B
Baud Rate: 21 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u: 30 (units 10 meters)
Length 62.5u:15 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: AGILENT
Vendor OUI: 00:30:d3
Vendor PN: HFBR-5720L
Vendor Rev:
Wavelength: 0 (units nm)
Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: A00107001
Date Code: 020313
DD Type: 0x0
Enh Options: 0x0
To display detailed information for GbE port 0 on an FR4-18i router blade:
CS48000:admin> sfpshow 10/ge0
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist
Encoding: 1 8B10B
Baud Rate: 21 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u: 30 (units 10 meters)
Length 62.5u:15 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: AGILENT
Vendor OUI: 00:30:d3
Vendor PN: HFBR-5720L
Vendor Rev:
Wavelength: 0 (units nm)
Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: A00143427
Date Code: 020511
DD Type: 0x0
Enh Options: 0x0