Brocade Fabric OS Command Reference Manual Supporting Fabric OS v6.3.0 (53-1001337-01, July 2009)

858 Fabric OS Command Reference
53-1001337-01
switchShow
2
FICON Persistent DID
This port has been disabled, because the switch could not obtain its
configuration domain ID during the fabric reconfiguration when ficonMode
was enabled. See the ficonMode help page for more information.
Fabric ID conflict
Two different fabrics have been assigned the same fabric ID (EX_Ports only).
Fabric ID oversubscribed
One fabric has been assigned two different fabric IDs (EX_Ports only).
AoQ Indicates that the F_Port has negotiated a link that is capable of quality of
service (QoS).
(logical) Indicates a logical port. The switchshow output shows all logical ports
currently present in the logical switch. The command displays -1 for the slot
for logical ports and the user port number for slot port. The logical port
numbers are not persistent and may change when the logical interswitch
links (LISLs) are deleted and recreated. A logical port is shown to be in one of
the following states: E_Port (if the port is online), offline, or disabled. When
the port is disabled, a reason is provided.
When used with the -slot option, the command displays the following blade-specific information:
slot Slot number.
Blade Type Type of blade, for example, Core blade or AP blade. Refer to the slotShow
command for a listing of supported blade types.
ID A numeric blade ID that specifies the blade type. Refer to the slotShow
command for a listing of supported blade IDs.
Status Enabled or disabled.
Notes The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
On the Brocade 8000, the Proto column identifies the FCoE ports of the switch. For all FcoE ports,
the speed is 10 Gbps. The default configuration of an FCoE port is an F_Port configuration. After a
successful reboot switchShow displays all FCoE ports as online. For each FCoE port, the FCoE
controller WWN is shown. FCoE ports are not configurable with the Fabric OS port commands. Use
the fcoe commands instead.
If a port is configured as a long distance port, the long distance level is displayed in the format of
Lx, where x represents the long distance level number. See portCfgLongDistance for the level
description.
The port state for disabled E_Ports displays as In_Sync when the port is the interswitch link (ISL)
between a Brocade 48000 and a Brocade 24000. If the ISL is between a Brocade 48000 and a
Brocade 4100 or 200E, the disabled E_Port displays as No_Sync.
On a Brocade 7600 switch, if the SAS image is not consistent with the FOS image, the message
"SAS Virtualization Disabled" is displayed.
When a port is configured as an N_Port and is online, switchShow displays its type as an N_Port.
Also, switchShow displays the WWN of the border switch attached to this N_Port as a 24-bit Port
Identifier assigned to this port by the enterprise fabric.