Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

248 Fabric OS Command Reference
53-1001764-01
fabricLog
22
A3
The non-Principal switch is processing an RDI.
S0
The switch is in offline state.
P
Port state. Port states include the following:
PO
The port is offline.
P1
The port is online.
P2
Exchange Link Parameters (ELP) Accept Frame (ACC) received.
P3
Link reset occurred on master or E_Port.
I0
Trunk Initiator: Exchange Mark Timestamp (EMT) sent.
I1
Trunk Initiator: Exchange Trunking Parameters (ETP) Accept Frame (ACC)
received.
I2
Trunk Initiator: ETP sent.
I3
Trunk Initiator: Link reset occurred.
I4
Trunk Initiator: Link reset done on slave.
T0
Trunk Target: EMT received.
T1
Trunk Target: ETP received.
T2
Trunk Target: Link reset.
T3
Trunk Target: Link reset done on slave.
LD
Dynamic long distance ECP sent or received.
ESC
Exchange Switch Capabilities (ESC) state between P2 and P3.
Sn
Next switch state. Refer to switch states for valid states.
Pn
Next port state. Refer to port states for valid states.
Port
Port number, if applicable, or NA
Xid
OXID (Exchange ID) Port number, if applicable, or NA
Refer to the FC-SW-5 specification for more information on the port and switch states logged by this
command.