Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

718 Fabric OS Command Reference
53-1001764-01
portDPortTest
22
EXAMPLES To initiate the D_Port test on a single port:
switch:admin> portdporttest --start
To terminate the D_Port test on a single port:
switch:admin> portdporttest --stop
To display the runtime status for a single D_Port while the test is in progress:
switch:admin> portdporttest --show 42
D-Port Information:
===================
Port: 42
Remote WWNN: 10:00:00:05:33:13:2f:b4
Remote port: 26
Mode: Automatic
Start time: Wed Feb 2 01:41:35 2011
End time: Wed Feb 2 01:43:23 2011
Status: PASSED
============================================================
Test Start time Result EST(secs) Comments
============================================================
Electrical loopback 01:42:12 PASSED -- ---------
Optical loopback 01:43:10 PASSED -- ---------
Link traffic test 01:43:17 PASSED -- ---------
============================================================
Roundtrip link latency: 1108 nano-seconds
Estimated cable distance: 20 meters
To display D_Port summary information:
switch:admin> portdporttest --show all 42
Port State SFP Capabilities Test Result
=============================================
24 ONLINE E,O PASSED
26 ONLINE E,O RESPONDER
33 OFFLINE --- RESPONDER
SEE ALSO fabricLog, portCfg, portCfgDPort, portShow, switchShow