Brocade Fabric Watch Administrator's Guide - Supporting Fabric OS v7.0.x (53-1002153-02, March 2012)

62 Fabric Watch Administrator’s Guide
53-1002153-02
portThConfig command procedures
7
Area: Trunk Utilization
Set the high boundary to 75 percent and the alarms to Above and In-Between conditions.
These settings indicate if the 75 percent threshold is exceeded and for how long.
Areas: Primitive Sequence Protocol Error, State Changes, Utilization, Packet Loss
Use the default settings.
E_Port class default settings
Table 17 provides default settings for areas in the E_Port class.
Port fencing can be enabled or disabled for the following areas for the E_Port class:
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
TABLE 17 E_Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Cyclic redundancy
check (CRC)
Monitors the
number of CRC
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Invalid transmission
words (ITW)
Monitors the
number of invalid
words transmitted.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Class 3 discards
(C3TX_TO)
Class 3 discards
frames due to time
out or destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Link loss Monitors the
number of link
failures.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative
Out_of_range
Signal loss Monitors the
number of signal
loss errors.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range