Area: Class 3 (C3) Discards
Unlike the other areas, take a conservative approach for the C3 Discards area. Use the default
settings and configure the alarms for Above. The goal is to locate issues with the device or its
infrastructure, so monitor the data to help isolate issues. Port fencing is one of the
recommended solutions for isolating issues.
Area: Trunk Utilization
The Trunk Utilization area is new; therefore, recommended settings are not yet available. Use
the default settings, monitor the results, and adjust your settings accordingly.
Areas: Primitive Sequence Protocol Error, State Changes
These areas are not used for monitoring; therefore, leave the default alarm settings at 0.
FOP_Port and FCU_Port subclass default settings
Table 18 provides default settings for areas in the FOP_Port and FCU_Port subclasses.
Port fencing can only be enabled or disabled for the following areas for the FOP_Port and FCU_Port
class:
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
Class 3 Discards
TABLE 18 FOP_Port and FCU_Port class default settings
Area Description Default threshold
settings
Default alarm settings Threshold state
Cyclic redundancy
check (CRC)
Monitors the
number of CRC
errors.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Invalid transmission
words (ITW)
Monitors the
number of invalid
words transmitted.
Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100
Below: 0
Above: 0
Informative
Out_of_range
Class 3 discards
(C3TX_TO)
Class 3 discards
frames due to time
out or destination
unreachable.
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Below: 0
Above: 0
Informative
Out_of_range
Link loss Monitors the
number of link
failures.
Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50
Below: 0
Above: 0
Informative