fcPing
22
Successfully completed superping for all paths
SWITCH3--> SWITCH4 STATUS
---------------------------------------------------------
(2/7,2/EMB)[2] (30/EMB,30/8)[128] (40/9, 40/EMB)[128] SUCCESS
Successfully completed superping for all paths
To execute a SuperPing and print statistical coverage of each ISL and internal port along the potential
paths (in the example, a few errors are recorded on the ISLs 3/205->2/25, 3/204->2/27, 2/42->101/3, and
2/1->101/8, but the internal port analysis shows that errors are recorded on the internal port 0/284 in
domain 2, which is the potential faulty link):
switch:admin> fcping --allpaths -printisl 101
Pinging(size:12 bytes) destination domain 101 through all paths
PATH SWITCH1--> SWITCH2--> \
------------------------------------------------
1. ( 3/EMB, 3/123)[128] (165/96 ,165/99 )[128] \
2. ( 3/EMB, 3/205)[128] ( 2/25 , 2/1 )[128] \
3. ( 3/EMB, 3/205)[128] ( 2/25 , 2/42 )[128] \
4. ( 3/EMB, 3/204)[128] ( 2/27 , 2/42 )[128] \
5. ( 3/EMB, 3/204)[128] ( 2/27 , 2/1 )[128] \
SWITCH3 STATUS
---------------------------------
(101/16 ,101/EMB)[128] SUCCESS
(101/8 ,101/EMB)[128] FAILED
(101/3 ,101/EMB)[128] FAILED
4(101/3 ,101/EMB)[128] FAILED
101/8 ,101/EMB)[128] FAILED
Completed superping for all paths. Error found in few paths
ISL COVERAGE
-------------
SNO ISL STATUS
---------------------------------------------------
1 ( 3/123[128]-->165/96[128] ) SUCCESS(5/5)
2 ( 3/205[128]--> 2/25[128] ) FAILURE(7/50)
3 ( 3/204[128]--> 2/27[128] ) FAILURE(11/50)
4 (165/99[128] -->101/16[128] ) SUCCESS(5/5)
6 ( 2/42[128] -->101/3[128] ) FAILURE(10/67)
7 ( 2/1[128] -->101/8[128] ) FAILURE(8/33)
INTERNAL PORT COVERAGE
-----------------------
SNO DOMAIN INTRNL_PORT STATUS
-------------------------------------------
1 2 0/272 SUCCESS(40/40)
2 2 0/276 SUCCESS(44/44)
3 2 0/280 SUCCESS(30/30)
4 2 0/284 FAILURE(20/20)