Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

Fabric OS Command Reference 33
53-1001764-01
ag
2
_F_Ports _F_Ports
--------------------------------------------------------------
0 None None 1 1 N/A N/A
17 2 2 0 0 N/A N/A
--------------------------------------------------------------
Static N-Port to F-Port Mapping
N-Port F-Port
--------------------------------------------------------------
17 1
--------------------------------------------------------------
AG failover policy commands
To display failover policy settings for all N_Ports:
switch:admin> ag --failovershow
N_Port failover_bit
---------------------------
0 1
1 0
2 1
3 0
To set and display failover and failback policies on a single port:
switch:admin> ag --failoverenable 1
Failover policy is enabled for port 1
switch:admin> ag --failoverdisable 0
Failover policy is disabled for port 0
switch:admin> ag --failovershow 0
Failover on N_Port 0 is not supported
switch:admin> ag --failbackdisable 2
Failback policy is disabled for port 2
switch:admin> ag --failbackshow 2
Failback on N_Port 2 is not supported
switch:admin> ag --failbackenable 2
Failback policy is enabled for port 2
To display failback policy settings for all the N_Ports:
switch:admin> ag --failbackshow
N_Port failback_bit
---------------------------
0 0
1 1
2 0
3 1