802 Fabric OS Command Reference
53-1001764-01
portShow
22
fcrPresent=N fchbValid=Y
FCHB Control variables:
tinOrigOxid=0xFFFF tirOrigOxid=0xFFFF tinAckRxid=0xFFFF
tinAckOxid=0xFFFF allocChOxid=0xFFFF allocChOIdx=0x0000
tinTirOxid=0xFFFF
To display FICON FCUB information (FICON Images accessed through the tunnel)
switch:admin> portshow xtun 23 -ficon -fcub
FCUB (FICON Control Unit Block) Count = 29
FC Egress parms:
(0x) Side Path: devRange DevCnt Model \
=========== ==== ================== ======== ==== =====
0410083800 H 0x17630164010604** 00-0F 0x10 3490 \
0410047500 H 0x17630164010605** 00-0F 0x10 3490 \
0410048E80 H 0x17630164010606** 00-0F 0x10 3490 \
0410049700 H 0x17630164010607** 00-0F 0x10 3490 \
0410054000 H 0x17630164010004** - 0x00 0000 \
041006B100 H 0x17630864030600** 00-7F 0x80 3990 \
041006C000 H 0x17630864030601** 00-7F 0x80 3990 \
04100A4000 H 0x17630864030000** - 0x00 0000 \
0410072000 H 0x176308640E0600** - 0x00 0000 \
0410073100 H 0x176308640E0601** - 0x00 0000 \
0410075100 H 0x176308640E0602** - 0x00 0000 \
0410076880 H 0x176308640E0603** - 0x00 0000 \
0410078000 H 0x176308640E0604** - 0x00 0000 \
0410078880 H 0x176308640E0605** - 0x00 0000 \
041007A000 H 0x176308640E0606** - 0x00 0000 \
FC Egress parms:
Type LPE BL CHPID Tag V Ve P B P VC EGID
==== === == ===== ========== = == = = = == ====
TAPE Yes 00F0 0x15698E1E Y Y 2 0 1 02 000D
TAPE Yes 00F0 0x15B5E15F Y Y 2 0 2 02 000D
TAPE Yes 00F0 0x15D1509C Y Y 2 0 4 02 000D
TAPE Yes 00F0 0x150D3FDD Y Y 2 0 2 02 000D
UNKN No 00F0 0x15CDB71F Y Y 2 0 1 02 000D
DISK Yes 00F2 0x1538206F Y Y 2 0 4 02 0007
DISK Yes 00F2 0x15E44F2E Y Y 2 0 1 02 0007
UNKN No 00F2 0x159C196E Y Y 2 0 3 02 0007
UNKN No 00F2 0x152D3BA3 Y Y 2 0 3 02 0007
UNKN No 00F2 0x15F154E2 Y Y 2 0 4 02 0007
UNKN No 00F2 0x1595E521 Y Y 2 0 4 02 0007
UNKN No 00F2 0x15498A60 Y Y 2 0 3 02 0007
UNKN No 00F2 0x155C86A7 Y Y 2 0 1 02 0007
UNKN No 00F2 0x1580E9E6 Y Y 2 0 1 02 0007
UNKN No 00F2 0x15E45825 Y Y 2 0 3 02 0007
(output split and truncated)
To reset the Device Path Block statistics:
switch:admin> portshow xtun 16 -ficon -fdpb -clear