Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

848 Fabric OS Command Reference
53-1001764-01
portThConfig
22
LR
Link reset
TU
Trunk Utilization
Only the following areas are valid for VE_Ports.
UTIL
Port utilization
PKTLOSS
Packet loss
ST
State change
--set
Configures the Fabric Watch thresholds for monitoring a specified area for all
ports of a specified port type. When configuring a threshold, you must specify a
port type and area. The following operands are optional and valid only with the
--set option. Defaults are used unless you configure custom settings. Defaults
parameters vary depending on the area and platform. Refer to the Fabric Watch
Administrator's Guide for specific details.
-timebase time_base
Specifies the time interval between two samples to be compared. Valid intervals
include the following:
day
Samples are compared once a day.
hour
Samples are compared once every hour.
minute
Samples are compared once every minute.
-highthreshold -value value
Specifies the high threshold value for triggering a specified alert action. To change
the default value, provide an integer value.
-lowthreshold -value value
Specifies the low threshold for triggering a specified alert action. To change the
default value, provide an integer value.
-trigger above | below
Specifies the actions for in range port behavior. In range is defined as the space
above the low threshold and below the high threshold.
-action actions
Specifies the actions triggered by a configured event condition. Valid values
include one or more of the following actions. If more than one action is specified,
the actions must be separated by commas.
raslog
Event triggers a RASlog message.
snmp
Event triggers an SNMP trap.
email
Event triggers an e-mail.