bladeCfgGeMode
Configures a GbE port or a 10GbE port on the Brocade FX8-24 blade.
SYNOPSIS bladecfggemode --set mode -slot slot
bladecfggemode --show -slot slot | -all
bladecfggemode --help
DESCRIPTION Use this command to configure the GbE port mode on the Brocade FX8-24 extension blade or to display
the configuration. The mode configuration controls which ports are enabled.
NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
This command is supported only on the Brocade FX8-24 blade in a DCX or DCX-S4 chassis.
OPERANDS This command has the following operands:
--set mode
Sets the GbE port mode for a specified slot. Valid modes are one of the following:
1g
Enables the GbE ports ge0-ge9 (xge0 and xge1 are disabled).
10g
Enables the GbE ports xge0 and xge1 (ge0-ge9 ports are disabled).
dual
Enables the GbE ports ge0-ge9 and xge0 (xge1 is disabled).
-slot slot
Specifies the slot number for the FX8-24 blade. This operand is required when
setting the GbE port mode
--show
Displays the GbE port mode for the specified slots.
-slot slot
Displays the GbE port mode for a single slot.
-all
Displays the GbE port mode for all configured slots.
--help
Displays the command usage.
EXAMPLES To configure the Brocade FX8-24 blade in slot 4 in 1G mode:
switch:admin> bladecfggemode --set 1g -slot 4
To display the GbE port mode for the Brocade FX8-24 blade in slot 4:
switch:admin> bladecfggemode --show -slot 4
bladeCfgGeMode: Blade in slot 4 is configured in 10GigE Mode