Brocade Fabric OS Command Reference - Supporting Fabric OS v7.0.1 (53-1002447-01, March 2012)

944 Fabric OS Command Reference
53-1001764-01
snmpConfig
22
To block access to SNMPv1/2c
switch:admin> snmpconfig --disable snmpv1
switch:admin> snmpconfig --show
SNMPv1 community and trap recipient configuration:
Community 1: ram (rw)
Trap recipient: 172.26.4.84
Trap port: 162
Trap recipient Severity level: 5
Community 2: OrigEquipMfr (rw)
No trap recipient configured yet
Community 3: private (rw)
No trap recipient configured yet
Community 4: public (ro)
No trap recipient configured yet
SNMPv1:Disabled
REFERENCES Refer to the following publications for further information on SNMP:
Fabric OS MIB Reference
SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap"
RFC1157, "A Simple Network Management Protocol (SNMPv1)"
RFC1213, "Management information Base for Network Management of TCP/IP-based internets:
MIB-II"
RFC2574, "User-based Security Model (USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)"
SEE ALSO None