Brocade EZSwitchSetup Administrator's Guide v6.2.0 (53-1001193-02, April 2009)

18 EZSwitchSetup Administrator’s Guide
53-1001193-02
Configuring the switch
2
Typical Zoning is the default and the following procedure directs you to select Typical Zoning. When
you select Typical Zoning, the wizard automatically configures the zones for you and shows you
how to connect the devices to the switch. You can change the zoning configuration later, as
described in “Zoning management” on page 41.
Configuring zones on the switch
1. On the Select Zoning wizard, select Typical Zoning.
If you want to use one of the other zone settings, see “Editing the zoning configuration” on
page 42 for instructions on configuring Custom zoning; see the Web Tools Administrator’s
Guide for information on Advanced zoning.
2. Click Next.
The Specify Devices screen is displayed.
Specifying devices
On the Specify Devices screen (Figure 16), do the following.
1. Enter the number of HBA connections that you want to attach to the switch. Be sure to include
existing HBA connections, and any additional HBA connections you plan to make in the current
setup session. You can change this setting later if you want to add or remove HBA connections.
2. Enter the number of storage connections you want to attach to the switch. Be sure to include
existing storage connections, and any additional storage connections you plan to make in the
current setup session.You can change this setting later if you want to add or remove storage
connections.
EZSwitchSetup uses these values to verify that all your current and planned devices are
properly connected for the zoning scheme that will be created. Note that Typical zoning
ensures that every connected host device will be able to communicate with every connected
storage device.
3. Click Next. The Connect Devices screen is displayed (Figure 17 on page 20).