Brocade Web Tools Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000435-01, June 2007)

212 Web Tools Administrator’s Guide
Publication Number: 53-1000435-01
Configuring SNMP
17
To set trap levels
1. Open the Switch Administration window as described on page 31.
2. Click the SNMP tab.
FIGURE 96 SNMP tab
3. Select a trap level for a recipient from the corresponding Trap Level drop-down menu in the
SNMPv1 and SNMPv3 sections.
The level you select identifies the minimum event level that will prompt a trap.
4. Click Apply.
CONFIGURING SNMP INFORMATION
When you configure SNMP information for a Brocade 24000 or 48000 configured with two logical
switches, it is on a logical-switch basis. This means that for each logical switch, you must configure
SNMP information individually.
To change the systemGroup configuration parameters
1. Open the Switch Administration window as described on page 31.
2. Click the SNMP tab (see Figure 96).