Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

66 Fabric OS Message Reference
53-1000600-02
BM-1053
7
Severity INFO
BM-1053
Message <timestamp>, [BM-1053], <sequence-number>,, WARNING, <system-name>, Failed to
establish connection between CP and Application Processor. Faulting switch.
Probable Cause The control processor (CP) could not establish a connection to the application processor to
communicate.
Recommended
Action
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit.
Severity WARNING
BM-1054
Message <timestamp>, [BM-1054], <sequence-number>,, INFO, <system-name>, AP firmware
<Blade firmware> is not consistent with system firmware <System firmware>.
Auto-leveling AP firmware to match system firmware.
Probable Cause The policy of the specified blade is set to auto-level the blade firmware to the system firmware, so
either:
Blade firmware was detected to be different from CP firmware due to a firmware upgrade
The blade was just inserted and had a different firmware loaded
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
Severity INFO
BM-1055
Message <timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for AP. Faulting switch.
Probable Cause The firmwareDownload command on the application processor (AP) blade failed.
Recommended
Action
Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
DCX, 7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING
BM-1056
Message <timestamp>, [BM-1056], <sequence-number>,, INFO, <system-name>, AP is not
configured. Persistently disabling all ports on the switch.