EM-1016
12
EM-1016
Message <timestamp>, [EM-1016], <sequence-number>,, WARNING, <system-name>, Cold recovery
failed (
<Return code>).
Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot.
Recommended
Action
Monitor the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
EM-1017
Message <timestamp>, [EM-1017], <sequence-number>,, WARNING, <system-name>, Uncommitted
WWN change detected. Cold reboot required.
Probable Cause Indicates that a user did not commit a changed world-wide name (WWN) value prior executing a
reboot, power cycle, or firmwareDownload operation.
Recommended
Action
Change and commit the new WWN value.
Severity WARNING
EM-1018
Message <timestamp>, [EM-1018], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot <slot number> failed to retrieve current chassis type (<detailed
fault descriptor>/<PLACE HOLDER>/0x<PLACE HOLDER>).
Probable Cause Indicates that there was a failure to read the chassis type from the system.
Recommended
Action
Verify that the control processor (CP) blade is operational and is properly seated in its slot.
Severity CRITICAL
EM-1019
Message <timestamp>, [EM-1019], <sequence-number>,, WARNING, <system-name>, Current
chassis configuration option (
<Chassis config option currently in effect>)
is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync.
Probable Cause Indicates that the current chassisConfig option is not supported by the firmware on the standby
control processor (CP). This is true even if the standby comes up and appears to be operational.
High availability (HA) synchronization of the CPs will not be allowed.