92 Fabric OS Message Reference
53-1000600-02
EM-1065
12
Recommended
Action
Contact support.
Severity CRITICAL
EM-1065
Message <timestamp>, [EM-1065], <sequence-number>,, CRITICAL, <system-name>, SAS
Virtualization Services are not available due to incompatiblity between the FOS
and SAS versions <Slot number or blank for single board systems>.
Probable Cause The version of either the control processor firmware (CFOS) or the blade processor firmware (BFOS)
is not compatible with the Storage Application Services (SAS) or other application firmware
version(s).
Recommended
Action
Upgrade the FOS firmware or the SAS firmware with the firmwareDownload command. Refer to the
release notes for a compatible version of firmware.
Severity CRITICAL
EM-1066
Message <timestamp>, [EM-1066], <sequence-number>,, INFO, <system-name>, SAS
Virtualization Services are now available <Slot number or blank for single board
systems>.
Probable Cause The previously incompatible Fabric OS or Storage Application Services (SAS) firmware have been
upgraded and are now compatible.
Recommended
Action
No action is required.
Severity INFO
EM-2003
Message <timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The Id will be Switch for non-bladed systems.
Recommended
Action
On bladed systems, try reseating the specified FRU.
On nonbladed switches, reboot or power cycle the switch.
If the problem persists: