Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

102 Fabric OS Message Reference
53-1000600-02
FABR-1010
15
Recommended
Action
The fabric daemon will discard the EFP. The system will recover through the EFP retrial process.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
FABR-1010
Message <timestamp>, [FABR-1010], <sequence-number>,, WARNING, <system-name>, <error
description>.
Probable Cause Indicates that the errors occurred while cleaning up the request domain ID (RDI). The error
description provides further details. This message is rare and usually indicates a problem with the
Fabric OS.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
FABR-1011
Message <timestamp>, [FABR-1011], <sequence-number>, FFDC, ERROR, <system-name>, <error
description>.
Probable Cause Indicates that the Fabric OS is unable to inform the Fabric OS State Synchronization Management
module (FSSME) that the fabric is stable or unstable. This message is rare and usually indicates a
problem with the Fabric OS.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
FABR-1012
Message <timestamp>, [FABR-1012], <sequence-number>,, WARNING, <system-name>, <function
stream>: no such type, <invalid type>.
Probable Cause Indicates that the fabric is not in the appropriate state for the specified process. This message is
rare and usually indicates a problem with the Fabric OS.
Recommended
Action
The fabric daemon will take proper action to recover from the error.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING