Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 151
53-1000600-02
FICN-1008
23
FICN-1008
Message <timestamp>, [FICN-1008], <sequence-number>,, ERROR, <system-name>,
DevDiskEgr:FICON Purge Path received Path=<FICON PATH>.
Probable Cause FICON Purge Path received from the channel as a part of path recovery.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.
Severity ERROR
FICN-1009
Message <timestamp>, [FICN-1009], <sequence-number>,, INFO, <system-name>,
DevIng:CmdReject Sense Data rcvd:Path=<FICON PATH> LastCmds=0x<last four FICON
CCW Commands processed> Sense Data:Bytes0-0xB=0x<FICON device Sense Data bytes
0-11>.
Probable Cause Unit Check status received from device and a sense command was issued to read the sense data.
Recommended
Action
If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.
Severity INFO
FICN-1010
Message <timestamp>, [FICN-1010], <sequence-number>,, INFO, <system-name>,
DevDiskEgr:Device level exception flag found for Path=<FICON PATH>: Oxid=0x<FC
OXID value from the received Device Level Exception frame>.
Probable Cause A Device Level Exception frame received from the FICON Channel.
Recommended
Action
If there was a job or IO failure associated with this event, please contact your vendor's customer
support for assistance.
Severity INFO
FICN-1011
Message <timestamp>, [FICN-1011], <sequence-number>,, ERROR, <system-name>,
DevDiskIng:XRC Incorrect RRS SeqNum Rcvd Path=<FICON PATH> Expected=0x<expected
RRS sequence number> Received=0x<received RRS Sequence Number> Oxid=0x<FC Frame
OXID>.
Probable Cause The Control Unit/device presented a Read Record Set Sequence number different from the SDM's
expected sequence number.