FICU-1001
Message <timestamp>, [FICU-1001], <sequence-number>,, ERROR, <system-name>, <function
name>: config<config Set(key)|Get(key)| Save> failed rc = <error>.
Probable Cause Indicates that one of the configuration management functions failed. The key variable is part of the
Fabric OS configuration database and is for support use only. The error variable is an internal error
number.
Recommended
Action
Execute an haFailover on the switch if it has redundant control processors (CPs) or reboot the
switch. Run the supportShow command to check if your flash is full. If the flash is full, run the
supportSave command to clear the core files. Refer to the Fabric OS Command Reference for more
information on these commands.
Severity ERROR
FICU-1002
Message <timestamp>, [FICU-1002], <sequence-number>,, ERROR, <system-name>, <function
name>: Failed to get RNID from Management Server: Domain=<domain>, rc=<error>.
Probable Cause Indicates that the fibre connectivity control unit port (FICON-CUP) daemon failed to get the switch
request node ID (RNID) from the management server due to a Fabric OS problem. The domain
variable displays the domain ID of the target switch for this request node ID (RNID). The error
variable is an internal error number.
Recommended
Action
If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a
nonbladed switch, download a new firmware version using the firmwareDownload command. Refer
to the Fabric OS Command Reference for more information on this command.
Severity ERROR
FICU-1003
Message <timestamp>, [FICU-1003], <sequence-number>,, WARNING, <system-name>, <function
name>: <message> FICON-CUP License Not Installed: (<error>).
Probable Cause Indicates that the fibre connectivity control unit port (FICON-CUP) license is not installed on the
switch.
Recommended
Action
Run the licenseShow command to check the installed licenses on the switch. The switch cannot be
managed using FICON-CUP commands until the FICON-CUP license is installed. Contact your switch
supplier for a FICON-CUP license. Run the licenseAdd command to add the license to your switch.