Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

184 Fabric OS Message Reference
53-1000600-02
FSS-1004
28
Severity WARNING
FSS-1004
Message <timestamp>, [FSS-1004], <sequence-number>,, ERROR, <system-name>, Memory
shortage
Probable Cause Indicates that the system ran out of memory.
Recommended
Action
Run the memShow command to view memory usage.
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
FSS-1005
Message <timestamp>, [FSS-1005], <sequence-number>,, WARNING, <system-name>, FSS read
failure
Probable Cause Indicates that the read system call to the Fabric OS state synchronization (FSS) device failed.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
FSS-1006
Message <timestamp>, [FSS-1006], <sequence-number>,, WARNING, <system-name>, No FSS
message available
Probable Cause Indicates that data is not available on the Fabric OS state synchronization (FSS) device.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
FSS-1007
Message <timestamp>, [FSS-1007], <sequence-number>,, CRITICAL, <system-name>,
<component name>: Faulty Ethernet connection.