Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

190 Fabric OS Message Reference
53-1000600-02
FW-1004
30
Severity WARNING
FW-1004
Message <timestamp>, [FW-1004], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the
acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. If you receive a temperature-related message, check for an accompanying
fan-related message and check fan performance. If all fans are functioning normally, check the
climate control in your lab.
Severity INFO
FW-1005
Message <timestamp>, [FW-1005], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the speed of the fan has changed. Fan problems typically contribute to temperature
problems.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. Consistently abnormal fan speeds generally indicate that the fan is
malfunctioning.
Severity INFO
FW-1006
Message <timestamp>, [FW-1006], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically
contribute to temperature problems.
Recommended
Action
Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan
field-replaceable unit (FRU).
Severity WARNING