Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 193
53-1000600-02
FW-1035
30
Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has fallen below the low
boundary.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity WARNING
FW-1035
Message <timestamp>, [FW-1035], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has risen above the high
boundary. Frequent fluctuations in temperature might indicate a deteriorating SFP.
Recommended
Action
Replace the SFP.
Severity WARNING
FW-1036
Message <timestamp>, [FW-1036], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has changed from a value
outside of the acceptable range to a value within the acceptable range. Frequent fluctuations in
temperature might indicate a deteriorating SFP.
Recommended
Action
No action is required.
Severity INFO
FW-1037
Message <timestamp>, [FW-1037], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The
receive performance area measures the amount of incoming laser to help you determine if the SFP
is in good working condition or not. If the counter often exceeds the threshold, the SFP is
deteriorating.
Recommended
Action
Incoming laser fluctuations usually indicate a deteriorating SFP. If this message occurs repeatedly,
replace the SFP.