Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

198 Fabric OS Message Reference
53-1000600-02
FW-1051
30
FW-1051
Message <timestamp>, [FW-1051], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures. Frequent voltage fluctuations are an
indication that the SFP is deteriorating.
Recommended
Action
If you see frequent voltage fluctuations, replace the SFP.
Severity WARNING
FW-1052
Message <timestamp>, [FW-1052], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1113
Message <timestamp>, [FW-1113], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each
time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go
down. E_Port downs might be caused by transient errors.
Recommended
Action
Check both ends of the physical connection and verify that the SFPs and cables are functioning
properly.
Severity INFO
FW-1114
Message <timestamp>, [FW-1114], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.