Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

254 Fabric OS Message Reference
53-1000600-02
FW-1400
30
Recommended
Action
No action is required.
Severity INFO
FW-1400
Message <timestamp>, [FW-1400], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the flash usage percentage has changed. Flash increases and decreases slightly
with normal operation of the switch. Excessive permanent increases can lead to future problems.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1401
Message <timestamp>, [FW-1401], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the flash usage percentage has fallen below the low boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to
future problems.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1402
Message <timestamp>, [FW-1402], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the flash usage percentage has risen above the high boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to
future problems.
Recommended
Action
You might have to remove some unwanted files to create some flash space. Run the supportSave
command to remove files from the kernel space.
Severity WARNING