Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 293
53-1000600-02
Chapter
39
ICPD System Messages
ICPD-1001
Message <timestamp>, [ICPD-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: (
<function name>).
Probable Cause Indicates that the specified function failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command.
Reboot or power cycle the switch.
Severity ERROR
ICPD-1002
Message <timestamp>, [ICPD-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module> rc = <error>.
Probable Cause Indicates that an initialization of a module within the ICPD failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference for more information on this command.
Severity ERROR
ICPD-1003
Message <timestamp>, [ICPD-1003], <sequence-number>,, INFO, <system-name>, iSCSI
configuration has been committed by switch (
<domain id>).
Probable Cause Indicates that iSCSI configuration has been committed by a remote switch in the fabric.
Recommended
Action
No action is required.
Severity INFO
ICPD-1004
Message <timestamp>, [ICPD-1004], <sequence-number>,, WARNING, <system-name>, iSNS Client
service is detected on multiple switches in fabric.
Probable Cause Indicates that iSNS Client service is enabled on multiple switches in fabric.