Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

334 Fabric OS Message Reference
53-1000600-02
PDM-1011
54
PDM-1011
Message <timestamp>, [PDM-1011], <sequence-number>,, WARNING, <system-name>, File read
failed: <file name>, Length(read=<Number of character read>, expected=<Number of
characters expected>), errno=<errno returned by read>.
Probable Cause Indicates that the parity data manager (PDM) process could not read data from the specified file.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1012
Message <timestamp>, [PDM-1012], <sequence-number>,, WARNING, <system-name>, File write
failed: <file name>. Length(read=<Number of character read>, write=<Number of
characters written>), errno=<errno returned by write>.
Probable Cause Indicates that the parity data manager (PDM) process could not write data to the specified file.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1013
Message <timestamp>, [PDM-1013], <sequence-number>,, WARNING, <system-name>, File empty:
<File Name>
Probable Cause Indicates that the switch configuration file /etc/fabos/fabos.[0|1].conf is empty.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1014
Message <timestamp>, [PDM-1014], <sequence-number>,, WARNING, <system-name>, Access
sysmod failed.
Probable Cause Indicates that a system call to sysMod failed.