Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 391
53-1000600-02
SEC-1116
66
SEC-1116
Message <timestamp>, [SEC-1116], <sequence-number>,, ERROR, <system-name>, Fail to commit
failover.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1117
Message <timestamp>, [SEC-1117], <sequence-number>,, INFO, <system-name>, Fail to set
<data>.
Probable Cause Indicates that the switch failed to save the data received by the primary fabric configurations server
(FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user
authentication data.
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity INFO
SEC-1118
Message <timestamp>, [SEC-1118], <sequence-number>,, INFO, <system-name>, Fail to set
SNMP string.
Probable Cause Indicates that the SNMP string could not be set.
Recommended
Action
Usually this problem is transient. Retry the command.
Severity INFO
SEC-1119
Message <timestamp>, [SEC-1119], <sequence-number>,, INFO, <system-name>, Secure mode has
been enabled.
Probable Cause Indicates that the secure Fabric OS was enabled by the secModeEnable command.