Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

404 Fabric OS Message Reference
53-1000600-02
SEC-1186
66
SEC-1186
Message <timestamp>, [SEC-1186], <sequence-number>,, INFO, <system-name>, <action>
<action>
Configuration.
Probable Cause Indicates that the remote authentication dial-in user service (RADIUS/LDAP) configuration was
enabled or disabled as the primary authentication, accounting, and authorization (AAA)
mechanism.
Recommended
Action
No action is required.
Severity INFO
SEC-1187
Message <timestamp>, [SEC-1187], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized switch
<switch WWN> tries to join fabric.
Probable Cause Indicates that a switch connection control (SCC) security violation was reported. The specified
unauthorized switch attempts to join the fabric.
Recommended
Action
Check the switch connection control policy (SCC) policy to verify the switches allowed in the fabric.
If the switch should be allowed in the fabric but not included in the SCC policy, add the switch to the
policy. If the switch is not allowed access to the fabric, this is a valid violation message and an
unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your
enterprise security policy.
Severity INFO
SEC-1188
Message <timestamp>, [SEC-1188], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized device <device node name> tries to FLOGI to index/area
<port number> of switch <switch WWN>.
Probable Cause Indicates that a device connection control (DCC) security violation was reported. The specified
device attempted to login using fabric login (FLOGI) to an unauthorized port. The DCC policy
correlates specific devices to specific port locations. If the device changes connected port, the
device will not be allowed to login.
Recommended
Action
Check the DCC policy and verify that the specified device is allowed in the fabric and is included in
the DCC policy. If the specified device not included in the policy, add it to the policy. If the host is not
allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to
access your fabric. Take appropriate action, as defined by your enterprise security policy.
Severity INFO