Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

426 Fabric OS Message Reference
53-1000600-02
SULB-1004
69
SULB-1004
Message <timestamp>, [SULB-1004], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwarecommit has completed.
Probable Cause Indicates that the FirmwareCommit command is executed.
Recommended
Action
No action is required. Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1005
Message <timestamp>, [SULB-1005], <sequence-number>,, INFO, <system-name>, Current Active
CP is preparing to failover.
Probable Cause Indicates that the active CP is about to reboot. The standby CP is taking over as the active CP.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1006
Message <timestamp>, [SULB-1006], <sequence-number>,, INFO, <system-name>, Forced
failover succeeded. New Active CP is running new firmware.
Probable Cause Indicates that the previous standby has now become the active CP and is running the new firmware
version.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO
SULB-1007
Message <timestamp>, [SULB-1007], <sequence-number>,, INFO, <system-name>, Standby CP
reboots.
Probable Cause Indicates that the standby CP is rebooting with new firmware.
Recommended
Action
No action is required. The firmwareDownload command is progressing as expected.
Run the firmwareDownloadStatus command for more information.
Severity INFO