SYSC-1004
71
It could also indicate that the current option number could not be read from the chassis option
storage device (the world-wide name (WWN) card).
This message occurs only on the Brocade 24000 and 48000.
Recommended
Action
As indicated in the message, run the chassisConfig command to change to one that is valid on this
platform running this firmware. Note that the chassisConfig option 1 should be valid for all
platforms running any valid firmware.
Severity CRITICAL
SYSC-1004
Message <timestamp>, [SYSC-1004], <sequence-number>,, INFO, <system-name>, Daemon
<Daemon name to restart> restart successful
Probable Cause Indicates that a terminated daemon is restarted by system automatically.
Recommended
Action
Use the supportSave command to gather troubleshooting data. No further action is required.
Severity INFO
SYSC-1005
Message <timestamp>, [SYSC-1005], <sequence-number>,, WARNING, <system-name>, Daemon
<Daemon name to restart> is not restarted (Reason: <Restart failure reason>)
Probable Cause Indicates that a terminated daemon is not restarted, either due to restart limit is reached or restart
action fails
Recommended
Action
Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover
command to recover the system and limit the traffic disruption.
Severity WARNING