Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 449
53-1000600-02
TRCE-1007
73
TRCE-1007
Message <timestamp>, [TRCE-1007], <sequence-number>,, ERROR, <system-name>, Notification
of this CP has failed. Parameters temporarily out of synch with other CP.
Probable Cause Indicates that the active CP is unable to alert the standby CP of a change in trace status. This
message is only applicable to the Brocade 24000, and 48000.
Recommended
Action
This message is often transitory. Wait a few minutes and try the command again.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1008
Message <timestamp>, [TRCE-1008], <sequence-number>, FFDC, CRITICAL, <system-name>,
Unable to load trace parameters.
Probable Cause Indicates that the active CP is unable to read stored trace parameters.
Recommended
Action
Reboot the CP (dual-CP system) or restart the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity CRITICAL
TRCE-1009
Message <timestamp>, [TRCE-1009], <sequence-number>,, ERROR, <system-name>, Unable to
alert active CP that a dump has occurred.
Probable Cause Indicates that the standby CP is unable to communicate trace information to active CP. This
message is only applicable to the Brocade 24000 and 48000.
Recommended
Action
Run the haShow command to verify that the current CP is standby and the active CP is active.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
TRCE-1010
Message <timestamp>, [TRCE-1010], <sequence-number>,, ERROR, <system-name>, Traced fails
to start