Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 517
53-1000600-02
SULB-1031
8
Recommended
Action
firmwareDownload will continue after the switch has rebooted. Run the firmwareDownloadStatus
command to monitor progress. If the problem persists, contact your switch service provider.
Severity WARNING
SULB-1031
Message AUDIT, <timestamp>, [SULB-1032], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Relocating an internal firmware image on the CP.
Probable Cause Indicates that the switch has rebooted with the new firmware and is relocating the AP firmware.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1032
Message AUDIT, <timestamp>, [SULB-1032], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Relocating an internal firmware image on the CP.
Probable Cause Indicates that the switch has started firmware download to the co-CPU.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1033
Message AUDIT, <timestamp>, [SULB-1033], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Switch has completed relocating the internal firmware image.
Probable Cause Indicates that the firmwareDownload process has completed normally on the switch.
Recommended
Action
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.
Severity WARNING
SULB-1034
Message AUDIT, <timestamp>, [SULB-1034], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload timed out.
Probable Cause The error may be caused by a switch initialization issue after the internal image is relocated. It may
also be caused by an internal Ethernet issue or by persistent storage failure.