Brocade Web Tools Administrator's Guide v6.0.0 (53-1000606-01, April 2008)

Web Tools Administrator’s Guide 129
53-1000606-01
Managing performance graphs
9
For the Brocade 4100 or 5000 switch, you can enter up to eight LUN masks.
For the Brocade 48000 director, you can enter up to four LUN masks.
For all other switches running Fabric OS 4.x or v5.x, you can enter up to two LUN masks.
For switches running Fabric OS 3.x, you can enter up to three LUN masks.
6. Click OK.
The selected graph is displayed in the canvas.
Creating AL_PA Error Graphs
The AL_PA Error graph displays CRC errors for a given port and a given AL_PA. The AL_PA Error
graph is not supported on the following:
Brocade 200E, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, and 7600
Brocade 48000 with an FR4-18i, FC4-16IP, FC-18 or FC4-48 blade(s) installed
1. Open the Performance Monitoring window.
2. Click Performance Graphs> Advanced Monitoring> ALPA Error.
The ALPA Error Setup dialog box opens.
3. Navigate to a switch> slot> port in the Slot/Port or Alpa Selection List.
4. Click the port from the Slot/Port Selection List or an AL_PA from the Slot/Port Selection List,
and drag it into the “Enter/drag slot,port” field. You can also manually type the slot and port
number, in the format slot,port.
5. Click OK.
The AL_PA Error graph opens on the canvas.
Managing performance graphs
This section provides the following procedures for managing performance graphs:
Saving graphs to a canvas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Adding graphs to an existing canvas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Printing a single graph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Modifying graphs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Saving graphs to a canvas
Saving graphs is especially useful when you create customized graphs and do not want to re-create
them every time you access the Performance Monitoring window.
When you save graphs, you must save them to a canvas. The following procedure describes how to
save graphs to a new canvas.
1. Open the Performance Monitoring window.
2. Create basic or advanced Performance Monitor graphs, as described in “Creating basic
performance monitor graphs” on page 124 and “Creating advanced performance monitoring
graphs” on page 126.