Displays all field replaceable units (FRUs).
Synopsis
chassisshow
Availability
all users
Description
Use this command to inventory and display the FRU header content for each object in the chassis.
The header data is formatted into a record consisting of up to 13 lines. Refer to Table 5 for more
information about the lines and their meaning.
Operands
none
chassisShow
Table 5 Command output descriptions
Line Description
1Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE
(control processor), WWN (World Wide Name), or UNKNOWN.
Object number: Slot nn (for blades), Unit nn (for everything else).
If the FRU is part of an assembly, a brief description, in parenthesis, displays.
2 FRU header version number: Header Version: x
3 Value to calculate the object's power consumption: positive for power supplies and
negative for consumers. Power Consume Factor: -xxx
4 Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx
5 Serial number (up to 12 characters): Factory Serial Num: xxxxxxxxxx
6 FRU manufacture date: Manufacture:Day: dd Month: mm Year: yyyy
7 Date of the last FRU header update: Update: Day: dd Month: mm Year:
yyyy
8 Cumulative time, in days, that the FRU has been powered on: Time Alive:dddd
days
9 Current time, in days, since the FRU was last powered on: Time Awake:ddd days
10 Externally supplied ID (up to 10 characters): ID: xxxxxxxxxx
11 Externally supplied part number (up to 20 characters):
Part Num: xxxxxxxxxxxxxxxxxxxx
12 Externally supplied serial number (up to 20 characters):
Serial Num:xxxxxxxxxxxxxxxxxxxx
13 Externally supplied revision number (up to 4 characters): Revision Num: xxxx