HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

124 Fabric OS commands
System Services
Table 10 lists the System Services fields and their settings.
Descriptions of the system service (setting) fields are as follows:
Always send RSCN? Following the completion of loop initialization, a remote state
change notification (RSCN) is issued when FL_Ports detect the
presence of new devices or the absence of preexisting devices.
When set, a RSCN is issued upon completion of loop
initialization, regardless of the presence or absence of new or
pre-existing devices.
Do Not Allow AL_PA 0x00? This option disables AL_PA values from 0x00.
Table 10 Configure command System Services fields
Field Default Range
rstatd Off On/Off
rusersd Off On/Off
telnetd On On/Off
thad On On/Off
Disable RLS probing On On/Off
rstatd Dynamically enables or disables a server that returns system
operation information through remote procedure calls (RPC). The
protocol provides for a wide range of system statistics.
The retrieval of this information is supported by a number of
operating systems that support RPC. Most UNIX-based systems
(HP-UX, Irix, Linux, Solaris, and so on.) use the RUP and
RSYSINFO commands to retrieve the information. Refer to your
local system documentation for the appropriate usage of the
these or equivalent commands.
rusersd Dynamically enables or disables a server that returns information
about the user logged into the system through remote procedure
calls (RPC). The information returned includes user login name,
system name, login protocol or type, login time, idle time, and
remote login location (if applicable).
The retrieval of this information is supported by a number of
operating systems that support RPC. On most UNIX-based
systems (HP-UX, Irix, Linux, Solaris, and so on.) the command to
retrieve the information is rusers. Refer to your local system
documentation for the appropriate usage of this or an equivalent
command.
telnetd Used to enable or disable the telnet interface to a switch,
including sectelnet. If you are using SSH to manage a switch,
you can disable the telnet interface for greater security. The
default value is on (telnet enabled).
thad Dynamically enables or disables the HP Fabric Watch services.
Disable RLS probing Enables or disables FCP read link status (RLS) information
probing for F/FL_Port. It is disabled by default.