HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

148 Fabric OS commands
Displays diagnostic mode configuration.
Synopsis
diagmodeshow
Availability
all users
Description
Use this command to display the current settings for several diagnostic configuration parameters. This
command is most often used by burn-in scripts to display a summary of the configuration settings that were
in effect when the script was run.
NOTE: Any automated use of this command only should rely on the names of the specific variables, not
on their exact positions in the output. Earlier versions of this command listed
diag.mode.burnin.nExec instead of Burnin nExec and diag.mode.burnin.nExec instead of
Burnin passnum.
Operands
none
Examples
To display the diagnostic mode:
diagModeShow
switch:admin> diagModeShow
diag.mode* parameters saved in flash:
diag.mode.burnin = 0
diag.mode.burnin.level = 0
diag.mode.burnin.firstPowerUp = Thu Feb 28 01:36:12 2002
diag.mode.esd = 0
diag.mode.gbic = 0
diag.mode.splb = 0
diag.mode.lab = 0
diag.mode.mfg = 0
diag.mode.bplb = 0
diag.ports = TEST (type=INDEX, sz=512): 100.
Burnin passnum = 1
Burnin nExec = 0
Silkworm Mode = OFF
Disable Modes Print = OFF