HP StorageWorks Fabric OS 5.0.0 Command Reference Guide (AA-RW1MA-TE, May 2005)

Fabric OS 5.0.0 command reference guide 407
Displays the current address mask for end-to-end performance monitors on a port.
Synopsis
perfshowporteemask [slotnumber/]portnumber
Availability
all users
NOTE: This command requires a Performance Monitor license.
Description
Use this command to display the current mask shared across all end-to-end (EE) performance monitors of a
port. There are only two commands that can modify the value of the EE mask: perfSetPortEEMask
and perfCfgRestore.
The end-to-end mask has 12 fields:
The fields that are marked on are used to trigger end-to-end monitors. The default value of the EE mask is
all fields set to on.
Operands
This command has the following operand:
perfShowPortEEMask
TxSID Domain: on
TxSID Area: on
TxSID ALPA: on
TxDID Domain: on
TxDID Area: on
TxDID ALPA: on
RxSID Domain: on
RxSID Area: on
RxSID ALPA: on
RxDID Domain: on
RxDID Area: on
RxDID ALPA: on
slotnumber For bladed systems only, this operand specifies the slot number of the
port on which the monitor is to be added, followed by a slash (/).
portnumber Specifies the number of the port on which the monitor is to be
added, relative to its slot for bladed systems. Use switchShow for a
list of valid ports.